Search results for "Arterial blood"
showing 10 items of 55 documents
Endocannabinoid 2-arachidonoylglycerol is elevated in the coronary circulation during acute coronary syndrome
2019
Objectives The endocannabinoid system modulates coronary circulatory function and atherogenesis. The two major endocannabinoids (eCB), 2-arachidonoylglycerol (2-AG) and N-arachidonoylethanolamide (AEA), are increased in venous blood from patients with coronary artery disease (CAD). However, given their short half-life and their autocrine/paracrine mechanism of action, eCB levels in venous blood samples might not reflect arterial or coronary eCB concentrations. The aim of this cross-sectional study was to identify the local concentration profile of eCB and to detect whether and how this concentration profile changes in CAD and NSTEMI versus patients without CAD. Methods and results 83 patien…
Spontaneous echo contrast caused by platelet and leukocyte aggregates?
2001
Background and Purpose —Spontaneous echocardiographic contrast (SEC) is correlated to clinical thromboembolic events. We sought to determine the origin of SEC by utilizing direct analysis of left atrial blood. Methods —We examined the blood of 13 patients with and 19 without SEC. Blood samples were taken from the femoral vein and artery and from the right and left atria after transseptal puncture. Samples were incubated with fluorescence-labeled antibodies directed against the platelet (CD41a-PE, CD42b-PE, and CD62p-FITC) and leukocyte membrane epitopes (CD45-APC and CD14-FITC). The expressed epitopes were analyzed by dual laser flow cytometry immediately after blood withdrawal. Results —I…
Analysis of interleukin-6 and interleukin-8 in lung transplantation: correlation with nitric oxide administration.
2008
Introduction and Objectives. Primary graft dysfunction (PGD) following lung transplantation (LT) is associated with an activation of the inflammatory cascade and release of cytokines. Inhaled nitric oxide (iNO) provides specific pulmonary vasodilatation and improves oxygenation. Our objective was to verify whether administering iNO to LT patients modified the blood and bronchoalveolar lavage (BAL) interleukin (IL)-6 and -8 levels in the event of PGD. Materials and Methods. Thirty-two LT patients were randomized to the iNO treatment or the control group. Patients in the first group were given 10 ppm of iNO from the start of LT until 48 hours afterward. BAL and peripheral arterial blood sampl…
Evaluation of regional haemodynamics and alterations of vascular wall of the lower limbs in hypertensive subjects
1995
This study was designed to analyse the relationship between arterial hypertension and changes in arterial blood flow and vascular wall damage of the lower limbs in hypertensive patients with various degrees of hypertension. Six hundred and fifty-four hypertensive patients (421 males and 233 females) aged 35 to 70 years and 88 healthy subjects (63 males and 25 females) aged 39 to 60 years were studied. Strain-gauge plethysmography of the lower limbs was used to calculate arterial calf blood flow (RF), arterial calf blood flow after post-ischaemic hyperaemia (PF), basal and minimal vascular resistances (BVR and MVR), time to reach peak flow (tPF), time until 50% reduction of peak flow (tT1/2)…
Sources of human plasma cyclic AMP. Examinations before and after beta 2 adrenergic stimulation.
1981
Plasma cyclic AMP was measured in different vessels in seventeen volunteers before and after stimulation with terbutaline. Differences between arterial blood and blood from the hepatic vein, right ventricle, inferior vena cava and a cubital vein could not be demonstrated. Only in the renal vein was the concentration of cyclic AMP decreased. Our results indicate that cyclic AMP is not generated from any specific isolated organ and that changes in cyclic AMP after subcutaneous injection of terbutaline reflect a general influence of this drug.
Feasibility of cuff-free measurement of systolic and diastolic arterial blood pressure
2011
We validated a prototype cuff-free device for noninvasive estimation of blood pressure (BP). The system assumed a linear relation between BP values and the inverse of arterial blood pulse transit time, measured as time interval between the R wave on the electrocardiograph and the onset of the peripheral pulse wave on a finger plethysmogram. Thirty-three healthy subjects were analyzed at rest and during increasing stress exercise. To estimate subject-specific linear model parameters, the system was calibrated ad personam with reference to BP measures obtained by a cuff sphygmomanometer. High correlation values (R2= 0.89 and 0.78 for systolic and diastolic BP, respectively) and differences co…
Optical coherence tomography-based retinal vessel analysis for the evaluation of hypertensive vasculopathy
2013
Purpose Evaluation of retinal vessels in cardiovascular disease traditionally relies upon funduscopy, but more recently digital photo analysis has expanded the spectrum. As spectral domain optical coherence tomography (OCT) allows an in-vivo assessment of retinal tissue and its vessels on a histological scale, our study aimed at using this tool for the analysis of the retinal vasculature. Methods Circumferential peripapillary OCT scans (3DOCT-2000; Topcon Inc., Tokyo, Japan), with centration on the optic nerve head, were taken from 20 eyes (20 participants) with normal blood pressure and 20 eyes (20 participants) with arterial hypertension above 120 mmHg (mean blood pressure). The diameter …
Accuracy of delivered versus preset minute ventilation of portable emergency ventilators.
1989
The accuracy of delivered minute volume (VE) ventilation of portable emergency ventilators (PEV) was evaluated. Five PEV from three manufacturers were adapted to an artificial lung for varying compliance and resistance. Each PEV was tested in the "no airmix" (pure oxygen) and "airmix" (approximately 60% oxygen) setting at different frequencies and VE. Measurement of delivered VE (VEdel) was made using a pneumotachograph and digital integration of the flow values greater than 1 min (maximal error +/- 2%). Maximal inspiratory pressure (Pinsp) was measured with a transducer. Two PEV from one manufacturer produced severe hyperventilation when used at low VE (i.e., in children). Two other PEV fr…
LED-bed therapy of cardiovascular disorders: a volunteer study
2020
Studies of the physiological response of human half-body illumination by a specially designed bed comprising large number of LEDs emitting in the red and near infrared spectral range were carried out in a group of 32 volunteers comprising healthy subjects and hypertension patients. Blood pressure, heart rate and arterial blood oxygen saturation, as well as the bed surface temperature were continuously monitored during the measurement sessions with and without aluminum foil cover on the bed surface. None of the volunteers exhibited any notable changes in the heart rate and blood oxygenation during the procedures. The LightStim LED-bed session did not produce changes of arterial pressure in n…
Dynamic computed tomography: a novel technique to study lung aeration and atelectasis formation during experimental CPR
2002
Objective: To develop an image based technique to study the effect of different ventilatory strategies on lung ventilation and alveolar recruitment during cardiopulmonary resuscitation (CPR). Design: (1) Technical development of the following components: (a) construction of an external chest compression device, which does not interfere with CT imaging, and (b) development of a software tool to detect lung parenchyma automatically and to calculate radiological density parameters. (2) Feasibility studies: three strategies of CPR ventilation were performed and imaged in one animal each (pigs, 25 kg): volume-constant ventilation (VCV), no ventilation, or continuous airway pressure (CPAP). One m…